Heat loss calculations & heat loss surveys to MIS 3005-D

One Heat Loss produces independent, room-by-room heat loss calculations to MIS 3005-D and BS EN 12831 for heat pumps, boilers, radiators and underfloor heating, from £75 + VAT. Work from your drawings, our survey form or a site visit. We don't sell heating equipment, so the numbers are only ever about your building.

Three ways to get your heat loss calculation

Route 01

Send your drawings

From £125 + VAT

Email floor plans and elevations. We take measurements from the drawings and build a detailed, room-by-room calculation tailored to the property's design. Ideal for new builds, extensions and architects.

Route 02

Complete our survey form

From £75 + VAT

No drawings? Fill in our comprehensive property form and we'll use that data to create the heat loss calculation and size the heating to suit.

Route 03

Book a site visit

From £300 + VAT

We visit, measure every room and record the building fabric and existing radiators in person, capturing the details a plan can't show. Best for older, listed and commercial buildings.

Prices vary with property size and project requirements. Email us for a fixed quote, or read our guide to heat loss survey costs.

What a heat loss calculation tells you

A heat loss calculation works out how many watts each room loses through its walls, floor, roof, windows and doors, and through ventilation, on the coldest day you design for. Add the rooms together and you have the building's design heat load: the number a heat pump or boiler has to be sized to.

Get it wrong and the system is either oversized, which costs more to buy and short-cycles, or undersized, so rooms never reach temperature. Heat pumps run at low flow temperatures, so the radiators or underfloor heating in every room also have to be sized from the same figures.

What's in our reports

  • Room-by-room heat loss in watts, to MIS 3005-D
  • Whole-building design heat load for sizing the heat pump or boiler
  • The design temperatures, U-values and ventilation rates used, set out clearly
  • Emitter guidance: radiator and underfloor heating outputs at your flow temperature
  • Optional before-and-after modelling of insulation upgrades
  • A report your MCS installer can use directly

Standards and software

Every calculation follows MIS 3005-D, the MCS design standard for heat pump systems, and the BS EN 12831-1:2017 heat load method, with UK design temperatures for the property's location. We produce calculations in the industry's recognised design tools, including Spruce, Heat Engineer Software and Easy MCS, and we're accredited with GreenPro, Elmhurst Energy and the IAA.

Who we work with

Homeowners checking a heat pump quote or planning a retrofit. Heating installers outsourcing design and surveys. Architects, builders and developers who need heat loss figures from drawings. Project managers running multi-site public and commercial estates.

What installers and clients say

“Stephen was incredibly professional and efficient when conducting our heat loss assessment, ensuring every detail was covered with precision. The information he provided was not only accurate but also comprehensive, helping us make informed decisions. His expertise and attention to detail were truly exemplar, making the entire process seamless and stress-free.”
Mark DenmanJMR Heating & Energy
“I have worked with Stephen for a number of years on a sub contract basis completing both site surveys and heat loss calculations. One Heat Loss have been professional, punctual and offer excellent value to any business. I am pleased to recommend Stephen and One Heat Loss to any and all potential customers.”
Paul GaddGhps
“Having worked with One Heat Loss on a regular basis we have found them to be both professional and knowledgeable. They have assisted us on several difficult projects, providing Heat Loss Surveys that are comprehensive and allow us to design heating systems that are efficient and cost effective for our customers.”
Damon BlakemoreBlakemore Plumbing and Heating
“We recently engaged One Heat Loss for our commercial heat loss calculations, and we couldn’t be more satisfied with their service. From start to finish, their team demonstrated exceptional professionalism and expertise. They provided detailed and accurate calculations, ensuring our project stayed on track and within budget.”
David HartshorneTechnical Operations Manager

Heat loss calculation FAQs

How much does a heat loss calculation cost?
Prices start from £75 when you complete our property survey form, £125 when we work from your building drawings, and £300 for a site visit, all plus VAT. The final price depends on the size of the property and what the project needs, so email us the details for a fixed quote.
Is your heat loss calculation MCS compliant?
Yes. Every calculation is carried out room by room to MIS 3005-D, the MCS heat pump design standard, using the BS EN 12831 method. The report can go straight into an MCS installer's design pack.
Can I use it for a Boiler Upgrade Scheme application?
Boiler Upgrade Scheme grants are paid on MCS-certified installations, and MCS requires the system to be designed to MIS 3005-D. Our calculations are produced to that standard, so your installer can use them for the BUS paperwork.
What do you need from me?
For a drawings-based calculation: floor plans, elevations and, if you have them, sections and a specification of walls, floors, roof and glazing. For the survey-form route we send you a structured questionnaire. For a site visit we just need access to the property.
Do you only do heat pumps?
No. The same room-by-room heat loss figure is used to size boilers, radiators and underfloor heating. We also model before-and-after scenarios so you can see the effect of insulation upgrades before committing to them.
Do you work for installers?
Yes. Many of our clients are heating installers who outsource heat loss calculations and site surveys to us on a subcontract basis, so their own engineers can stay on the tools.
Is your free online calculator the same thing?
No. The free calculator uses typical U-values to give an indicative figure, which is useful for checking a radiator or a quote. It is not a certified MIS 3005-D calculation and can't be used for MCS or BUS.
Get a number you can build on

Let's size it right, the first time.

Send your drawings, fill in the form, book a visit or book an air test. Email us and we'll come back with a price.

Email info@oneheatloss.co.uk → WhatsApp 07496 898392